Friday, June 8, 2018

HP acu drive listing errors. Smart array

I have current config
HP Proliant bl460gen6 with controller smart array p711m Ubuntu OS
There are 35 hdd drives configured in raid 1+0 with 1 disk in spare
usually i monitor status of raid with default command




hpacucli ctrl all show config




and if it found failed disk i replace it.

By chance I noticed that the diodes are signaling of broken two HDDs on the storage system.
At the same time, hpacucli in the report said that all HDD were normal.
After googling the problem I got another version of the hpacucli syntaxis like




hpacucli ctrl slot=2 ld 1 show




After its implementation, it confirmed the existence of problematic HDD
Replacing one HDD continued to monitor the situation, the recovering of the raid took place in the normal mode, however, the numbering of the HDDs in the list is given the wrong with doubling drives numbers




Replaced HDD is in slot 2



hpacucli ctrl all show config



  Smart Array P711m in Slot 2
array A (SATA, Unused Space: 0 MB)
logicaldrive 1 (61.9 TB, RAID 1+0, Recovering, 75% complete)
physicaldrive 1E:1:1 (port 1E:box 1:bay 1, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:1 (port 1E:box 1:bay 1, SATA, 4000.7 GB, OK)

physicaldrive 1E:1:2 (port 1E:box 1:bay 2, SATA, 4000.7 GB, Rebuilding)
physicaldrive 1E:1:2 (port 1E:box 1:bay 2, SATA, 4000.7 GB, Rebuilding)
physicaldrive 1E:1:3 (port 1E:box 1:bay 3, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:3 (port 1E:box 1:bay 3, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:4 (port 1E:box 1:bay 4, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:4 (port 1E:box 1:bay 4, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:5 (port 1E:box 1:bay 5, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:5 (port 1E:box 1:bay 5, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:6 (port 1E:box 1:bay 6, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:6 (port 1E:box 1:bay 6, SATA, 4000.7 GB, OK)

physicaldrive 1E:1:7 (port 1E:box 1:bay 7, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:7 (port 1E:box 1:bay 7, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:8 (port 1E:box 1:bay 8, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:8 (port 1E:box 1:bay 8, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:9 (port 1E:box 1:bay 9, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:9 (port 1E:box 1:bay 9, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:10 (port 1E:box 1:bay 10, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:10 (port 1E:box 1:bay 10, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:11 (port 1E:box 1:bay 11, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:11 (port 1E:box 1:bay 11, SATA, 4000.7 GB, OK)

physicaldrive 1E:1:12 (port 1E:box 1:bay 12, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:12 (port 1E:box 1:bay 12, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:13 (port 1E:box 1:bay 13, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:13 (port 1E:box 1:bay 13, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:14 (port 1E:box 1:bay 14, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:14 (port 1E:box 1:bay 14, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:15 (port 1E:box 1:bay 15, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:16 (port 1E:box 1:bay 16, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:17 (port 1E:box 1:bay 17, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:18 (port 1E:box 1:bay 18, SATA, 4000.7 GB, OK)

physicaldrive 1E:1:19 (port 1E:box 1:bay 19, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:20 (port 1E:box 1:bay 20, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:21 (port 1E:box 1:bay 21, SATA, 4000.7 GB, OK, active spare)


hpacucli ctrl slot=2 ld 1 show



     Smart Array P711m in Slot 2
array A
Logical Drive: 1

Size: 61.9 TB
Fault Tolerance: 1+0
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 256 KB
Full Stripe Size: 4352 KB
Status: Recovering, 78% complete
MultiDomain Status: OK
Caching: Enabled

Unique Identifier:
Disk Name: /dev/sda
Mount Points: None
Logical Drive Label:
Mirror Group 0:
physicaldrive 1E:1:1 (port 1E:box 1:bay 1, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:2 (port 1E:box 1:bay 2, SATA, 4000.7 GB, Rebuilding)
physicaldrive 1E:1:3 (port 1E:box 1:bay 3, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:4 (port 1E:box 1:bay 4, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:5 (port 1E:box 1:bay 5, SATA, 4000.7 GB, OK)

physicaldrive 1E:1:6 (port 1E:box 1:bay 6, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:7 (port 1E:box 1:bay 7, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:8 (port 1E:box 1:bay 8, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:9 (port 1E:box 1:bay 9, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:10 (port 1E:box 1:bay 10, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:11 (port 1E:box 1:bay 11, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:12 (port 1E:box 1:bay 12, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:13 (port 1E:box 1:bay 13, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:14 (port 1E:box 1:bay 14, SATA, 4000.7 GB, OK)
physicaldrive 1E:1:1 (port 1E:box 1:bay 1, SATA, 4000.7 GB, OK)

physicaldrive 1E:1:2 (port 1E:box 1:bay 2, SATA, 4000.7 GB, Failed)
physicaldrive 1E:1:3 (port 1E:box 1:bay 3, SATA, 4000.7 GB, OK)


Whats get wrong, how i can fix it and why different hpacucli commands return different HDD status

No comments:

Post a Comment

linux - How to SSH to ec2 instance in VPC private subnet via NAT server

I have created a VPC in aws with a public subnet and a private subnet. The private subnet does not have direct access to external network. S...