Saturday, July 28, 2018

hp proliant - Replace HDD in "predictive failure" state with spare HDD in HP Smart Array P400 controller



I have an HP Smart Array P400 RAID controller with six physical disks configured in RAID 5. Four of the physical disks are in "OK" state, one is in "Predictive Failure" state, and one is in "spare" state:



logicaldrive 1 (3.6 TB, RAID 5, OK)


physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 1 TB, Predictive Failure)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 1 TB, OK)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 1 TB, OK)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 1 TB, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 1 TB, OK)
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 1 TB, OK, spare)


Is it safe to add (hpacucli controller slot=6 array A add drives=1:6) a "spare" drive to RAID 5 and once its drive type changes from "Spare Drive" to "Data Drive", then remove (either physically or maybe with hpacucli controller slot=6 array A remove drives=1:1) the HDD with the "Predictive Failure" state?



Answer



Wait until the drive fails or physically remove or replace it.



Seeing "Predictive Failure" in an indication to order a new drive.



The best course of action if to get a new drive and replace the failing drive with it (and not to rely on the spare rebuild).


No comments:

Post a Comment

linux - How to SSH to ec2 instance in VPC private subnet via NAT server

I have created a VPC in aws with a public subnet and a private subnet. The private subnet does not have direct access to external network. S...